• Users Online: 276
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
CASE REPORT
Year : 2018  |  Volume : 4  |  Issue : 2  |  Page : 111-114

Staged humerus lengthening with monolateral fixation followed by a circular frame: Technique of fixator change


1 Louisiana State University Health Science Center, Children's Hospital of New Orleans, New Orleans, LA, USA
2 International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Maryland, USA

Correspondence Address:
John E Herzenberg
International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, Maryland 21215
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jllr.jllr_12_18

Rights and Permissions

Monolateral external fixator (MEF) has been commonly used for limb lengthening in both upper and lower extremities. Since MEF can only lengthen or shorten the bone, sagittal, coronal, and torsional deformities need to be corrected acutely at the time of MEF application. Acute correction, particularly torsional correction, may endanger the radial or peroneal nerves. Gradual correction of torsion may be safely achieved using a circular external fixator (CEF) frame. We present a case study of humeral lengthening with derotation to describe a technique, whereby it is possible to first lengthen with MEF and then derotate with CEF. This is a case report of a 14-year-old boy with a history of neonatal sepsis and growth arrest of the proximal humerus that led to a short right humerus and loss of external rotation. Humerus lengthening was achieved (6.6 cm) using MEF. Conversion to CEF was done after the distraction phase and prior to regenerate bone consolidation. Two 2/3 rings were connected to the proximal and distal fixation half-pins, and then the six connecting struts were added. The rotation deformity correction was then performed gradually to achieve 60° of external rotation. The described technique to convert the MEF into CEF is versatile and can be employed in the clinic safely and without sedation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed262    
    Printed16    
    Emailed0    
    PDF Downloaded3    
    Comments [Add]    

Recommend this journal